Step 8:
To fix Encoded BCH1 and Calculated BCH1, use the below template:
1
100000100111001000001
01
Step 9:
Convert the entire template to hex format using Calculator. We should get: E52881
Step 10:
Replace BECF05 with E52881 in the 22-digit hex code. We have:
Since the values of Encoded BCH1 and Calculated BCH1 are exactly the same, the above 22-
digit hex is valid.
Step 11:
To program the ELT, we enter:
06 -22 6C6620052000166E528810
Note: 06 = write ID command
-22 = length of ID
Replace these digits with
Calculated BCH1 (bits N/A)